2 parameters for communication, 2 parameters for communication -3 – Topcon GTS-823A User Manual

Page 94

Advertising
background image

8-3

8 PARAMETERS SETTING MODE

8.1.2 Parameters for communication

Serial port.

Setting parameters for RS232C

Setting parameter for RC

Menu

Selecting Item

Contents

S.Port

RS232C /RC

Selecting serial port, RS-232C connector 1(6pins) or Remote
controll system.

Menu

Selecting Item

Contents

B. Rate

1200 / 2400 / 4800 /
9600

Select the baud rate.

Data. L

7 / 8

Select the data length seven digits or eight digits.

Parity

none / odd / even

Select the parity bit.

Stop Bit

1 / 2

Select the stop bit.

Delimit

ETX / CRLF

Select the option OFF or ON for carriage return and line feed
when collecting measurement data with a computer.

REC-A/B

A / B

Select the option to record the data.
REC-A : The measurement is started and new data is output.
REC-B : The data being displayed is output.

Protocol

OFF / ON

When communicating to an external device, the protocol for
handshaking can omit the [ACK] coming from the external
device so data is not sent again.
OFF : Omit the [ACK]
ON : Standard

NEZ-REC

Std / Exp

Record coordinates in standard or Data with slope distance
and horizontal angle data.

Trk Stat

OFF / ON

Selecting additional information of utility to measuring data
such as tracking status or not.
If such utility is selected, electric circular level graphic will not
be displayed whenever tilted over.
OFF :No additional information
ON

:Additional information

Menu

Selecting Item

Contents

Channel

1 / 2 / 3

Sets communication channel when using with remote controll
system.

V.Search

15 / 30

Selecting the vertical range for searching a prism when using
with remote controll system.
15

:

±15

°

30

:

±30

°

RC

S / M

Selecting the number of the RC-2RII to use one or more than
one when using with RC-2RII.
S

: Single RC-2RII use

M : Multiple RC-2RII use

The following settings are effective for standard measurement modes only.
You are requested to set each time of each application such as EXTERNAL LINK (in Program
modes) or other application software.

Advertising
This manual is related to the following products: