1 angle offset, 1 angle offset -15 – Topcon GTS-823A User Manual

Page 73

Advertising
background image

5-15

5 PROGRAM MODES

5.6.1 Angle Offset

This mode is useful when it is difficult to set up the prism directly, for example at the center of a tree.
Place the prism at the same horizontal distance from the instrument as that of point A0 to measure.
To measure the coordinates of the center position, operate the offset measurement after setting the
instrument height/prism height.

Operating procedure

Operation

Display

1

Press [F6](MORE) key from programs menu
to get to the next page of programs.

[F6]

2

Press [F2](OFFSET) key.

[F2]

3

Press [F1](ANGLE OFFSET) key.

[F1]

Prism P

Prism height

Instrument height

Occ. Point

When measuring coordinates of ground point A

1

:Set the instrument height/prism height.

When measuring coordinates of point A

0

: Set

the instrument height only. (Set the prism height
to 0 ).

When sighting to A

0

, you can select one of two

ways. [HOLD] is to fix vertical angle to the prism
position even updown the telescope position, and
[FREE] is to gear vertical angle to the updown of
telescope movement. In case following the
vertical angle to the movement of telescope,
SD(Slope Distance) and VD(Vertical Distance)
will be changed according to the movement of
telescope.

Programs

F1 BS p 4/7

F2 STORE p

F3 REM p

F4 MLM p MORE

Programs

F1 LINE p 7/7

F2 OFFSET p

F3 EXT.LINK p

MORE

OFFSET MEASUREMENT

1.ANGLE OFFSET

2.DIST. OFFSET

3.PLANE OFFSET

4.COLUMN OFFSET

ANGLE OFFSET

1.FREE V-ANGLE

2.HOLD V-ANGLE

Advertising
This manual is related to the following products: