Table 10 - YK 155 External static pressure

Standard drive

Oversized drive

External Static Pressure (Pa)

275

300

325

350

375

400

425

450

475

500

m

3

/h

RPM (kW) RPM (kW) RPM (kW) RPM (kW) RPM (kW) RPM (kW) RPM (kW) RPM (kW) RPM (kW) RPM (kW)

6800

699

1.47

719

1.55

739

1.63

758

1.71

777

1.79

795

1.86

813

1.94

830

2.01

847

2.09

863

2.16

7650

729

1.82

749

1.92

768

2.01

787

2.1

806

2.19

824

2.28

841

2.37

858

2.46

875

2.55

8500

764

2.25

782

2.35

800

2.45

818

2.55

9350

10200

External Static Pressure (Pa)

25

50

75

100

125

150

175

200

225

250

m

3

/h

RPM (kW) RPM (kW) RPM (kW) RPM (kW) RPM (kW) RPM (kW) RPM (kW) RPM (kW) RPM (kW) RPM (kW)

6800

564

1

587

1.07

610

1.15

633

1.23

655

1.31

677

1.39

7650

560

1.14

583

1.23

605

1.31

627

1.39

648

1.48

669

1.56

690

1.65

710

1.74

8500

559

1.31

584

1.41

606

1.5

628

1.6

649

1.69

669

1.78

689

1.87

708

1.97

727

2.06

746

2.16

9350

610

1.72

633

1.83

654

1.94

675

2.04

694

2.14

713

2.24

732

2.34

750

2.45

767

2.55

785

2.65

10200

661

2.21

683

2.33

703

2.45

722

2.56