TROY Group MAN-EXT2000 User Manual

Page 227

Advertising
background image

Reloading the Firmware C-3

When you type a CTRL-D to exit the remote console, the
file

XJET.BIN

will then be loaded into the print server.

The red TEST LED will blink during the load process and
will go out when the process is complete.

If the red LED does not go out after about two minutes,
check to make sure that you correctly entered all parameters
and that your network connections are good. Then power
the print server off and then on again, enter the

SET LOAD

ENABLE

command, and exit the remote console to retry the

download.

Downloading from a Windows NT or UNIX
Host Computer using Master Mode tftp

To download the print server firmware from a Windows NT
or UNIX system using master mode tftp, first copy the file
XJET.BIN to that host. Make sure that tftp is started by
checking the appropriate files on your system (on Windows
NT, TCP/IP and Simple TCP/IP Services must be enabled in
the Network Control Panel); with UNIX, tftp must be
enabled in your

/etc/services

file and possibly in another

configuration file, such as

/etc/inetd.conf

. Refer to

your system documentation or the UNIX man pages for
additional information.

Important Note:

Master mode tftp requires V3.46 or later

firmware plus 4.6 or later boot firmware. Do a

SHOW

VERSION

command in the print server console to verify

which version you are using.

To download the firmware from Windows NT, enter the
following command:

tftp - i

ipaddr put file password

Advertising