2-10 Installation

6 7 8 9

DE9 Male

(female pinouts are in

reverse order)

XConnect 100 (DE9)

Printer (DB25)

DE9

DTE

DCE

pin

Signal

Signal

pin

pin

1

Not used

Not used

-

-

2

Receive Data

Transmit Data

2

3

3

Transmit Data

Receive Data

3

2

4

DTR out

DSR in

6

20

5

Signal Ground

Signal Ground

7

7

6

DSR in

DTR out

20

6

7

RTS out

CTS in

5

4

8

CTS in

RTS out

4

5

9

Not used

Not used

-

-

Basically, the cable must connect input signals (e.g., Receive
Data) on the TROY XCD print server to the equivalent
output signals (e.g., Transmit Data) on the device and vice-
versa.

If you are connecting a printer to the second serial port (S2)
on the XConnect 100, you must first disable console mode on
that port. This is done by using the console command

SET

PORT S2 CONSOLE DISABLED

and then typing the command

EXIT

to exit the console (refer to Chapter 3 and Appendix A

for information on using the console). To re-enable the
console function, you must either enter the command

SET

PORT S2 CONSOLE ENABLED

using TELNET, DEC MOP or

the TROY XCD XCONFIG NetWare utility, or reset the unit
back to factory defaults.