Operating the Equipment Locally

Page 4-68

Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder

ST.TM.E10076.3

Table 4.68: Baud Rate Options

Selected Option

Description

Selected Option

Description

1200

1200 Baud rate.

9600

9600 Baud rate.

2400

2400 Baud rate.

19200

19200 Baud rate.

4800

4800 Baud rate.

38400

38400 Baud rate.

RS232 PID Option

The RS232 PID option is selected from the Data A - RS232 Menu by

pressing the RS232 PID softkey. The option is used for entering or

updating data PIDs. Enter a PID using the softkeys, then press the Enter

softkey to accept it.
To be DVB compliant, PIDs below 32 are reserved. Therefore PIDs 32 to

8191 are available for use. In the event of a clash, one of the PIDs will be

changed by the Encoder’s internal checking algorithm.

Delay Option

The Delay option is selected from the Data A - RS232 Menu by pressing

the Delay softkey. The option cannot be changed.

SNMP oid index Option

The SNMP oid

8

index option is selected from the Data A - RS232 Menu by

pressing the SNMP oid index softkey.
All option modules have the same SNMP oid with the exception of one byte

which identifies which slot the module is in. An MEM expects the data

module to be in slot two or three in the previous version of the Encoder.

Therefore, slots one and two in this Encoder have been allocated to

correspond directly to slots two and three in the previous Encoder.
In this Encoder the data module can be allocated to slot one, making it

inaccessible to an MEM. This variable allows the on-board data module to

be apparently moved around - to a slot in which it may be referenced by

the MEM.

Table 4.69: SNMP oid index Options

Selected Option

Description

Min:

1

Max:

7

Oid index

4.10.3 Data B - RS422 Menu

Encoding Option

To access the Encoding option, press the Encoding softkey in the
Data B - RS422

Menu. This enables the RS-422 synchronous data channel

to be switched On or Off.

8