Buzzer test, Fault-finding, Fault-finding philosophy – TANDBERG E5714 User Manual

Page 221: Preliminary checks, 5 fault-finding, 1 fault-finding philosophy, 2 preliminary checks

Advertising
background image

Preventive Maintenance and Fault-finding

Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder

Page 6-7

ST.TM.E10076.3

Buzzer Test

Press the Buzzer softkey to access the option which immediately causes a

buzzer to sound. Press any key (except the Quit softkey) to turn the

buzzer off. Press the Quit softkey to return to the menu.

6.5

Fault-finding

6.5.1

Fault-finding Philosophy

It is the objective of this chapter to provide sufficient information to enable

the operator to rectify apparent faults or else to identify the suspect

module, where possible. Some basic procedures are provide to follow in

the event of a suspected Encoder failure. It is assumed that fault-finding

has already been performed at a system level and that other equipment

units have been eliminated as the possible cause of the failure (see

relevant System Manual).

WARNING…

DO NOT REMOVE THE COVERS OF THIS EQUIPMENT. HAZARDOUS VOLTAGES ARE PRESENT

WITHIN THIS EQUIPMENT AND MAY BE EXPOSED IF THE COVERS ARE REMOVED. ONLY

TANDBERG TELEVISION TRAINED AND APPROVED SERVICE ENGINEERS ARE PERMITTED TO

SERVICE THIS EQUIPMENT.

CAUTION…

Do not remove the covers of this equipment. Unauthorised maintenance or the use of non-approved

replacements may affect the equipment specification and invalidate any warranties.

This manual does not include any maintenance information or procedures

which would require the removal of covers.
If the following information fails to clear the abnormal condition, call a

Service Engineer or contact Customer Services using the information given

in the preliminary pages of this manual.

6.5.2

Preliminary Checks

Always investigate the failure symptoms fully, prior to taking remedial

action. Fault diagnosis for the equipment operator is limited to the

following tasks, since the operator should NOT remove the covers of the

equipment:
1. Check the front panel Power LED. If this is not lit:

a) Replace the fuse in the power connector at the rear panel (see

Section 6.5.3, User Accessible Fuse Replacement).

NOTE…
Only replace the fuse once. If it blows again contact Customer Services.

b) Replace external equipment, power source and cables by

substitution to check their performance.

Advertising
This manual is related to the following products: