LNB Lo Freq Option

To access the LNB Lo Freq option, press the LNB Lo Freq softkey in the

IRD Demod Menu

.

This value should be set to the LNB’s lower local oscillator frequency. If the

LNB has only one local oscillator then both the LNB Lo and LNB Hi Freq

options should be set to that value.

LNB Hi Freq Option

To access the LNB Hi Freq option, press the LNB Hi Freq softkey in the

IRD Demod Menu

.

This value should be set to the LNB’s higher local oscillator frequency.

LNB Switch Freq Option

To access the LNB Switch Freq option, press the LNB Switch Freq softkey

in the

IRD Demod Menu

.

If the LNB has two local oscillators, this value sets the frequency above

which the higher local oscillator will be used. The switching between the

local oscillators is by a 22 kHz tone.

LNB Supply

To access the LNB option, press the LNB softkey in the

IRD Demod Menu

.

Table 4.140: LNB Supply Options

Selected Option

Description

Disabled

LNB Supply Off

Enabled

LNB Supply On

Boost

LNB Supply (approximately 1 V higher than enabled)

Search Range Option

NOTE…
The search range is not applicable if the Sat Input is set to IF.

To access the Search Range option, press the Search Range softkey in

the

IRD Demod Menu

.

Table 4.141: Search Range Options

Valid Input Range

Description

Min

0.1 kHz

Max

5.0 kHz

BER Threshold Option

To access the BER Threshold option, press the BER Threshold softkey in

the

IRD Demod Menu

. This sets the BER level that, if exceeded, generates a

BER Alarm.