Lcd display test, Keyboard test, Fail relay test – TANDBERG E5714 User Manual

Page 220: Alarm relay test, Alarm led test

Advertising
background image

Preventive Maintenance and Fault-finding

Page 6-6

Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder

ST.TM.E10076.3

Figure 6.2: Finding the Diagnostics Menu

LCD Display Test

Press the LCD Display softkey to access the option and then press any

key to cycle through the test patterns and to return to the menu.

Keyboard Test

Press the Keyboard softkey to access the option and then press each

softkey and keypad key in turn. The display shows the name of each key

pressed. Press the Quit softkey to return to the menu.

Fail Relay Test

Press the Fail Relay softkey to access the option and then press any key

(except the Quit softkey) to toggle the fail relay on and off. Press the Quit

softkey to return to the menu. The relay can usually be heard clicking as it

changes state. The relay is connected to the rear panel ALARM connector

– see Chapter 2, Installing the Equipment for the connector pin-out

details.

Alarm Relay Test

Press the Alarm Relay softkey to access the option and then press any

key (except the Quit softkey) to toggle the alarm relay on and off. Press

the Quit softkey to return to the menu. The relay can usually be heard

clicking as it changes state. The relay is connected to the rear panel

ALARM connector – see Chapter 2, Installing the Equipment for the

connector pin-out details.

Alarm LED Test

Press the Alarm LED softkey to access the option and then press any key

(except the Quit softkey) to toggle the front panel Alarm LED on and off.

Press the Quit softkey to return to the menu.

Diagnostics…

Setup ...
Errors...

Ops ...
Configs

More ...

Advanced Menu