B.10 Option Modules

B.10.1 M2/EOM2/AUDLIN Additional Audio and Linear PCM

Option Module

See Section B.1.2, Audio for details.

B.10.2 M2/EOM2/DAT RS-232 and RS-422 Data Input

Option

Asynchronous Data Input

A 9-way, D-type female connector provides an RS-232 asynchronous,

serial communications data input interface.

Table B.30: RS-232 Asynchronous Data Input Specification

Item

Specification

Safety status

SELV

Type

ITU-T V.24/V.28 (RS-232D) asynchronous serial data

Connector designation

ASYNC

Connector type

9-way D-type female

Supported baud rates

1200, 2400, 4800, 9600, 19200, 38400 baud

Control mechanism

XON/XOFF

Time-stamp

Not supported

Synchronous Data Input

A 15-way, D-type female connector provides an RS-422 synchronous,

serial communications data input interface.

Table B.31: RS-422 Synchronous Data Input Specification

Item

Specification

Safety status

SELV

Type

ITU-T V.11 (RS-422), synchronous serial data and external clock

Connector designation

SYNC

Connector type

15-way D-type female

Clock frequencies

n x 64 kbit/s from 64 kbit/s to 2048 kbit/s (selectable)
or
n x 56 kbit/s from 56 kbit/s to 1792 kbit/s (selectable)

Time-stamp

Not supported

Operation modes

Bit-pipe - Transport packet alignment and byte alignment relative
to the incoming bit-stream are arbitrary.