Satellite modulator related errors, H.10 satellite modulator related errors – TANDBERG E5714 User Manual

Page 310

Advertising
background image

Error Messages

Page H-8

Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder

ST.TM.E10076.3

Error Message

Action to Take

Level Clipping Left

Level Clipping Right

Audio input level on the reported channel is too high and is being clipped.
Reduce the audio input level.

Embedded Source 1

Embedded Source 2

Embedded Source 3

Embedded Source 4

AC-3 Input Invalid

No Digital Input

Check the audio input cable is correctly fitted, and that the audio source is
functioning. If the fault persists call Service Engineer.

Mux FIFO Overflow

Duplicate PID

Invalid PID

Mux Bit-Rate too low

Audio Un-Calibrated

Power Encoder off, then check that the Base Board and any audio modules are
firmly seated in the chassis. Do this by firmly pressing them from the rear of the
Encoder into the chassis. Power on the Encoder. If the fault persists call Service
Engineer.

H.10 Satellite Modulator Related Errors

Table H.8: Satellite Modulator Error Messages

Error Message

Action to Take

Config Update

Processor Stopped

Hardware Fault

FPGA Configuration

FPGA Temperature

DLL Unlocked

Module Uncalibrated

Modulation Fault

Synthesiser Unlocked

ALC Error

Input Clock Fault

Input Sync Fault

TSI FIFO

DPC FIFO

Parameter Fault

IF Card Missing

Power Encoder off, then check that the Base Board and Satellite Modulator are
firmly seated in the chassis. Do this by firmly pressing them from the rear of the
Encoder into the chassis. Power on the Encoder. If the fault persists call Service
Engineer.

Advertising
This manual is related to the following products: