23 diagnostic register – Texas Instruments Dual/Single Socket CardBus and UntraMedia Controller PCI7621 User Manual

Page 253

Advertising
background image

11−15

11.23 Diagnostic Register

This register programs the M and N inputs to the PLL and enables the diagnostic modes. The default values for M
and N in this register set the PLL output to be 80 MHz, which is divided to get the 40 MHz and 20 MHz needed by
the flash media cores. See Table 11−16 for a complete description of the register contents. All bits in this register are
reset by GRST only.

Bit

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

Name

Diagnostic

Type

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R/W

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Name

Diagnostic

Type

R

R

R

R

R

R

R

R/W

R

R

R

RW

RW

RW

RW

RW

Default

0

0

0

0

0

0

0

1

0

0

0

0

0

1

0

1

Register:

Diagnostic

Type:

Read-only, Read/Write

Offset:

54h

Default: 0000 0105h

Table 11−16. Diagnostic Register Description

BIT

SIGNAL

TYPE

FUNCTION

31−17

TBD_CTRL

R

PLL control bits. These bits are reserved for PLL control and test bits.

16

DIAGNOSTIC

RW

Diagnostic test bit. This test bit shortens the PLL clock CLK_VALID time and shortens the card detect
debounce times for simulation and TDL.

15−11

RSVD

R

Reserved. Bits 15−11 return 0s when read.

10−8

PLL_N

RW

PLL_N input. The default value of this field is 01h.

7−5

RSVD

R

Reserved. Bits 7−5 return 0s when read.

4−0

PLL_M

RW

PLL_M input. The default value of this field is 05h.