Printer Operation

Calibrate the Printer

11342L Rev. 8 6/4/2004

105SL User Guide

35

Calibrate the Printer

There are five different ways that the printer can be calibrated. You may calibrate the printer as
needed.

Auto-calibration occurs when the printer feeds media after the printhead is closed and

when the printer is first turned on (see

MEDIA POWER UP on page 53

and

HEAD

CLOSE on page 54

for options). The printer automatically sets the value it detects for the

spaces between labels. This type of calibration also happens as part of both the sensor
profile and media and ribbon sensor calibration procedures.

Long Calibration, which you select by pressing PAUSE then CALIBRATE, calibrates

the printer for media length, media type (continuous or non-continuous), and print mode
(thermal or direct thermal transfer) and updates the sensor values. This calibration is the
same as what is performed when Calibration is selected for the

MEDIA

POWER

UP

and

HEAD

CLOSE

parameters. For more information, see

MEDIA POWER UP on page 53

or

HEAD CLOSE on page 54

.

Short Calibration, which is a selection for the

MEDIA

POWER

UP

and

HEAD

CLOSE

parameters, uses current sensor values rather than detecting the spaces between labels and
resetting the sensors. This calibration sequence may use fewer labels than the long
calibration sequence, but it is less reliable because the values that are stored in the sensors
could be incorrect. For more information, see

MEDIA POWER UP on page 53

or

HEAD

CLOSE on page 54

.

Sensor Profile Calibration, which you select through the front panel, auto-calibrates the

printer and prints a media sensor profile. See

SENSOR PROFILE on page 49

for

instructions.

Media and Ribbon Sensor Sensitivity Calibration, which you select through the front

panel, resets the sensitivity of the sensors to detect correctly the media and ribbon that you
are using. See

Media and Ribbon Sensor Calibration on page 36

for instructions. If you

change the type of ribbon and/or media, you might need to reset the sensitivity of the
media and ribbon sensors. When the sensors are at their new sensitivity, the printer
performs an auto-calibration.