Configuration

Overview

11342L Rev. 8 6/4/2004

105SL User Guide

43

Exit Setup Mode

To leave Setup Mode, complete these steps:

1.

Press

SETUP/EXIT

.

The LCD displays

SAVE CHANGES

.

2.

Press the Plus (+) or Minus (–) to display the save options (

Table 4

).

3.

Press

NEXT/SAVE

to select the displayed choice.

When the configuration and calibration sequence is done,

PRINTER READY

displays.

Table 4 • Save Options When Leaving Setup Mode

LCD Display

Description

PERMANENT

Permanently saves the changes. Values are stored in the printer even when
power is turned off.

TEMPORARY

Saves the changes until you change them again or until power is turned off.

CANCEL

Cancels all changes from the time you pressed

SETUP/EXIT

except the

darkness and tear-off settings (if they were changed).

LOAD DEFAULTS

Sets all parameters other than the network settings back to the factory defaults.

Note •

Loading factory defaults causes the printer to auto-calibrate.

LOAD LAST SAVE

Loads values from the last permanent save.

DEFAULT NET

Sets the wired and wireless network settings back to factory defaults.