Adjust and Calibrate Sensors

11342L Rev. 8 6/4/2004

105SL User Guide

37

7.

Close the printhead, trapping the ribbon in this position.

8.

Press the (+) key. The LCD shows “CALIBRATING PLEASE WAIT.”

9.

When this part of the calibration process is completed, the LCD reads “RELOAD ALL
CONTINUE.”

10.

Open the printhead. Pull the liner until a label is positioned between the media sensors.

11.

Return the ribbon to its proper position.

12.

Close the printhead. Press the (+) key to perform the next part of the calibration sequence.
“MEDIA AND RIBBON CALIBRATE” displays. The printer is calibrated when the
media stops feeding.

13.

Press SETUP/EXIT to leave Setup Mode. Choose “permanent” when SAVE CHANGES
displays.

14.

Press NEXT/SAVE to save the changes.
The printer does a calibration equivalent to pressing

CALIBRATE

; during this process,

the printer determines the label length. To see the new readings on the new scale, print a
sensor profile.