Appendix, Printer interface technical information, Rs-232/rs-422/rs-485 serial data port – Zebra Technologies XiIII Series User Manual

Page 101: L›c‹à, 3ulqwhu ,qwhuidfh 7hfkqlfdo ,qirupdwlrq

Advertising
background image

Zebra XiIII-Series User’s Guide

93

®®l›c‹à

3ULQWHU ,QWHUIDFH 7HFKQLFDO ,QIRUPDWLRQ

565656 6HULDO 'DWD 3RUW

The connections for these standard interfaces are made through the
DB-25S connector on the rear panel. For all RS-232 input and output
signals, the printer follows both the Electronics Industries Association’s
(EIA) RS-232 specifications and the Consultative Committee for
International Telegraph and Telephone (CCITT) V.24 standard signal level
specifications.

The following table shows the pin configuration and function of the rear
panel serial data connector on the printer.

Pin No.

Description

1

FG (frame ground) for cable shield

2

TXD (RS-232 transmit data) output from printer

3

RXD (RS-232 receive data) input to printer

4

RTS (RS-232 request to send) output from printer

6

DSR (data set ready) input to printer

7

SG (signal ground) for RS-232

9

+5 VDC source output (1 Amp maximum)

11

SGR (signal ground reference) for RS-422/RS-485

13

Data input B(-); RS-422/RS-485

14

Data output B(-); RS-422/RS-485

16

Data input A(+); RS-422/RS-485

19

Data output A(+); RS-422/RS-485

20

DTR (RS-232 data terminal ready) output from printer

NOTE: Pins 5, 8, 10, 12, 15, 17-18, 21-25 are unused and unterminated.