&OHDQLQJ WKH 6HQVRUV

The media, ribbon, and label available sensors should be cleaned on a
regular basis to ensure proper operation of the printer. To locate these
sensors, refer to Figure 27 on page 65, Figure 6 on page 11, and Figure 7
on page 12. Brush/vacuum any accumulated paper lint and dust off of
these sensors.

&OHDQLQJ WKH 6QDS 3ODWH

Clean the snap plate to remove label adhesive or a label that has adhered to
the underside of the snap plate.

Refer to Figure 28.

1. Insert a small-blade screwdriver or similar tool into the loop on the left

side of the snap plate. Lift the snap plate.

CAUTION: Take care not to bend, twist, or otherwise deform the

loops!

2. Repeat step one on the right side of the snap plate.

3. Remove the snap plate from the printer.

4. Clean the snap plate with cleaning solvent and a soft cloth.

Refer to Figure 29.

5. To reinstall the snap plate, insert the two tabs on the bottom of the snap

plate into the two slots of the media pathway.

6. Slide the snap plate toward you.

7. Press down on the loops to lock the snap plate into place.