4 protection commands and queries, Remote interface reference – American Magnetics 03300PS-430-601 High Stability Integrated Power Supply System User Manual

Page 137

Advertising
background image

Rev. 5

119

Remote Interface Reference

SETUP Configuration Commands and Queries

ABsorber?

Returns “0” indicating that an energy absorber is not present in the

system, or “1” indicating that an energy absorber is present.

CONFigure:RAMP:RATE:UNITS {0|1}

Sets the preferred ramp rate time units. Sending “0” selects seconds. A “1”

selects minutes. “0” is the default value. The selected units are applied to

both the Model 430 Programmer display and the appropriate remote

commands.

RAMP:RATE:UNITS?

Returns “0” for ramp rates displayed/specified in terms of seconds, or “1”

for minutes.

CONFigure:FIELD:UNITS {0|1}

Sets the preferred field units. Sending “0” selects kilogauss. A “1” selects

tesla. “0” is the default value. The selected field units are applied to both

the Model 430 Programmer display and the applicable remote commands.

FIELD:UNITS?

Returns “0” for field values displayed/specified in terms of kilogauss, or “1”

for tesla.

CONFigure:IPNAME <

system name

>

Sets the system name (also known as host name or computer name), the

name by which the Model 430 Programmer is identified on a network.

Note

If the system name value is changed, the Model 430 Programmer

power must be cycled off for at least 5 seconds and then back on to

complete the change. The new value will be used internally

immediately (even before cycling power off and back on), but the

IPNAME? query will return the previous system name until the

Model 430 Programmer is restarted.

IPNAME?

Returns the system name (also known as host name or computer name).

4.5.4

Protection Commands and Queries

The Protection Commands and Queries provide read/write access to all

protection settings which can be accessed under the Settings Protection

submenu. See section 3.10.3.6 for more information regarding the settings

protection features of the Model 430 Programmer.

Advertising