4 technical data – VEGA VEGAMET 515V User Manual

Page 6

Advertising
background image

6

VEGAMET 515V

1.4 Technical data

Power supply

Operating voltage

Unom = 20 … 53 V AC, 50/60 Hz

= 20 … 72 V DC

Power consumption

approx. 20 VA or approx. 15 W

Meas. data input

Number

2 inputs

Input type

active two-wire input, digital (VBUS) (sensor is

powered by VEGAMET)

Possible sensors (loop powered)

pressure transmitters, ultrasonic sensors,

radar sensors

Voltage

approx. 25 V DC

Current limitation

at approx. 7 W, short-circuit proof

Min. adjustment delta

2 % of sensor range (hydrostatic)
5 mm (ultrasonic, radar)

Connection cable

2-wire standard cable (screening recommen-

ded)

max. cable length

1000 m

max. resistance per wire

20

Correction signal input

Number

2 inputs

Function

switching signal to trigger corrections
or special relay modes via
external switching contact

Voltage

5 V (from instrument)

Current

5 mA

External cable resistance

150

Current output

Number

3 outputs

Function

analogue output of the processing results

Range

individually adjustable in the range of 0 … 20 mA

Load

max. 500

Resolution

1 µA

Linearity error

0.05 % (relating to 20 mA)

Temperature error

0.05 %/10 K (relating to 20 mA)

Voltage output

Number

3 outputs

Function

analogue output of the processing results

Range

individually adjustable in the range of 0 … 10 V

Current

max. 1 mA

Resolution

0.5 mV

Linearity error

0.05 % (relating to 10 V)

Temperature error

0.06 %/10 K (relating to 10 V)

Product description

Advertising