5 Connecting to power supply
VEGADIF 65 • Foundation Fieldbus
36130-EN-130417
5.7 External housing with version IP 68
I²C
Display
Typ:
1 2
5 6 7 8
Bus
Sim.
4
5
6
1
2
3
Fig. 43: Electronics and connection compartment, single chamber housing
1 Plug connector for VEGACONNECT (I²C interface)
2 Spring-loaded terminals for connection of the external indication VEGADIS
61
3 Cable gland to the sensor
4 Ground terminal for connection of the cable screen
5 Spring-loaded terminals for Foundation Fieldbus connection
6 Simulation switch ("on" = simulation mode)
1 2 3 4
3
4
1
2
5
Fig. 44: Connection of the sensor in the housing base
1 Brown
2 Blue
3 Yellow
4 White
5 Shielding
Electronics and connec-
tion compartment
Terminal compartment for
sensor connection