PI Ignored

The PI (Paper Instruction) signal is used to control vertical paper motion.

Enable

(default). Causes the printer to interpret the eight data lines as

DVFU commands when the PI signal is true.

Disable

. Ignores the PI signal and treats the data as characters or control

codes.

Data Polarity

The Data Polarity parameter must be set to match the data polarity of your
host computer.

Standard

(default). Does not expect the host computer to invert the data.

Inverted

. Expects the data received on the data lines from the host

computer to be inverted. Ones become zeros, and zeros become ones.

Resp. Polarity

The Response Polarity parameter must be set to match the response polarity
of your host computer.

Standard

(default). Does not invert the response signal.

Inverted

. Inverts the response signal sent to the host computer.

Latch Data On

Specifies whether the data is read on the leading, middle, or trailing edge of
the data strobe signal. The default is Middle.

Prime Signal

Disable

(default). The parallel port will not perform a warm start (reboot) if

the host asserts the prime signal.

Enable

. The parallel port will perform a warm start (reboot) if the host

asserts the prime signal.

TOF Action

Reset

(default). A form feed is performed before a warm start when the

prime signal is asserted from the host. This setting is used only if the
prime signal parameter is enabled.

Do Nothing

. Nothing occurs before a warm start when the prime signal is

asserted from the host.

Buffer Size in K

Configures the amount of memory allocated for the Dataproducts parallel port
buffer. You can specify between 1, 2, 4, 8, 16, 32, 64, 128, and 256 Kbytes.