Table 24. SCETU0 Register

SCETU0 (S:ACh, SCRS = 1)
Smart Card ETU Register 0

Reset Value = 0111 0100b

Table 25. SCGT1 Register

SCGT1 (S:B5h, SCRS = 1)
Smart Card Transmit Guard Time Register 1

Reset Value = XXXX XXX0b

Table 26. SCGT0 Register

SCGT0 (S:B4h, SCRS = 1)
Smart Card Transmit Guard Time Register 0

Reset Value = 0000 1100b

7

6

5

4

3

2

1

0

ETU7

ETU6

ETU5

ETU4

ETU3

ETU2

ETU1

ETU0

Bit

Number

Bit

Mnemonic

Description

7-0

ETU[7:0]

ETU LSB
The Elementary Time Unit is (ETU[10:0] - 0.5*COMP)/f, where f is the Card CLK
frequency.
According to ISO7816, ETU[10:0] can be set between 11 and 2047.
The default reset value of ETU[10:0] is 372 (F = 372, D = 1).

7

6

5

4

3

2

1

0

GT8

Bit

Number

Bit

Mnemonic

Description

7-1

Reserved
The value read from these bits is indeterminate. Do not change these bits .

0

GT8

Transmit Guard Time MSB
Used together with the Transmit Guard Time LSB (see SCGT0 Register).

7

6

5

4

3

2

1

0

GT7

GT6

GT5

GT4

GT3

GT2

GT1

GT0

Bit

Number

Bit

Mnemonic

Description

7-0

GT[7:0]

Transmit Guard Time LSB
The minimum time between two consecutive start bits in transmit mode is
GT[8:0] * ETU.
According to ISO 7816, GT can be set between 11 and 266 (11 to 254+12 ETU).

Advertising