Er (see table 68) – Rainbow Electronics T89C5121 User Manual

Page 94

Advertising
background image

94

A/T8xC5121

4164G–SCR–07/06

Table 68. BDRCON Register

BDRCON
Baud Rate Control Register (9Bh)

Reset Value = XXX0 0000b

7

6

5

4

3

2

1

0

-

-

-

BRR

TBCK

RBCK

SPD

SRC

Bit

Number

Bit

Mnemonic

Description

7

-

Reserved
The value read from this bit is indeterminate. Do not set this bit

6

-

Reserved
The value read from this bit is indeterminate. Do not set this bit

5

-

Reserved
The value read from this bit is indeterminate. Do not set this bit.

4

BRR

Baud Rate Run Control bit
Clear to stop the Baud Rate.
Set to start the Baud Rate.

3

TBCK

Transmission Baud rate Generator Selection bit for first UART
Clear to select Timer 1 for the Baud Rate Generator.
Set to select internal Baud Rate Generator.

2

RBCK

Reception Baud Rate Generator Selection bit for first UART
Clear to select Timer 1 for the Baud Rate Generator.
Set to select internal Baud Rate Generator.

1

SPD

Baud Rate Speed Control bit for first UART
Clear to select the SLOW Baud Rate Generator when SRC = 1.
Set to select the FAST Baud Rate Generator when SRC = 1.

0

SRC

Baud Rate Source select bit in Mode 0 for first UART
Clear to select F

OSC

/12 as the Baud Rate Generator.

Set to select the internal Baud Rate Generator.