Reception (mode 0), Baud rate selection (mode 0) – Rainbow Electronics T89C5121 User Manual

Page 88

Advertising
background image

88

A/T8xC5121

4164G–SCR–07/06

Reception (Mode 0)

To start a reception in mode 0, write to SCON register clearing SM0, SM1 and RI bits
and setting the REN bit.

As shown in Figure 40, Clock is pulsed and the LSB (D0) is sampled on the RXD pin.
The D0 bit is then shifted into the shift register. After eight sampling, the MSB (D7) is
shifted into the shift register, and hardware asserts RI bit to indicate a completed recep-
tion. Software can then read the received byte from SBUF register.

Figure 40. Reception Waveforms (Mode 0)

Baud Rate Selection (Mode 0)

In mode 0, baud rate can be either fixed or variable.

As shown in Figure 41, the selection is done using M0SRC bit in BDRCON register.
Figure 42 gives the baud rate calculation formulas for each baud rate source.

Figure 41. Baud Rate Source Selection (Mode 0)

Figure 42. Baud Rate Formulas (Mode 0)

Write to SCON

TXD

RXD

RI

D0

D1

D2

D3

D4

D5

D6

D7

Set REN, Clear RI

0

1

M0SRC

BDRCON.0

PER

CLOCK

÷

6

To Serial Port

IBRG

CLOCK

Baud_Rate

=

6

(1-SPD)

32

(256 -BRL)

2

SMOD1

F

PER

BRL = 256

-

6

(1-SPD)

32

Baud_Rate

2

SMOD1

F

PER

a. Fixed Formula

b. Variable Formula

Baud_Rate =

6

F

PER

Advertising