SENA SS800 User Manual

Page 21

Advertising
background image

21

3)

Connect the other end of the cable to the serial port of the user’s computer.

4)

Run a terminal emulator program (i.e. HyperTerminal). Set up the serial configuration

parameters of the terminal emulation program as follows:

9600 Baud rate

Data bits 8

Parity None

Stop bits 1

No flow control

5)

Press the [ENTER] key.

6)

Enter your user name and password to log into the Super Series. The factory default user

settings are as follows.

Login: root

Password: root

Login: admin

Password: admin

192.168.161.5 login: root
Password:****
[email protected]:~#

7)

Upon authentication, the CLI are initially provided for configuration. For details on the CLI,

refer to the chapter 8. CLI Guide.

8)

“ss.edit” command will allow you to enter the text-menu driven interface and the menu

screen in Figure 2-15 is displayed.

[email protected]:~#ss.edit

------------------------------------------------------------------------------

Welcome to SS-800 configuration page
Current time: 08/22/2003 21:52:36

F/W REV.: v0.4.0

Serial No.: SS800438349-42944

MAC address: 00-01-95-04-19-5a

IP mode: DHCP

IP address: 192.168.14.7

------------------------------------------------------------------------------

Select menu:

1. Network configuration
2. Serial port configuration
3. PC Card configuration
4. System administration
5. Save changes
6. Exit without saving
7. Exit and apply changes
8. Exit and reboot
<Enter> Refresh

----->

Figure 2-15 The main menu screen (SS800)

From the main menu screen, the user may select the menu item for the configuration of the Super

Series parameters by typing the menu number and pressing the [ENTER] key. In the submenu screen,