4.2.11. Port Logging

With the port logging feature, the data sent through the serial port is stored to MEMORY, an ATA/IDE

fixed disk card, a SYSLOG server or a mounting point on an NFS server.

Enable/disable port logging

This parameter defines whether to enable or disable the port-logging feature. The factory default

setting is [disabled].

Port log storage location

The port log data can be stored to the Super Series internal memory, an ATA/IDE fixed disk card

inserted in PCMCIA slot, the mounting point on an NFS server or the SYSLOG server. If the internal

memory is used to store port log data, the port log data will be cleared when the Super Series is

turned off. To preserve the serial port log data, set the storage location to be the ATA/IDE fixed disk

card, SYSLOG server or NFS server. To do this, the user must configure the corresponding media in

advance. Unless the media is properly set up, the user will not be able to select a storage location

from the interface.

Port log buffer size

This parameter defines the maximum amount of port log data to be logged. When using internal

memory to store the log data, the total size of the port buffer cannot exceed 3200 Kbytes (i.e. sum of