SENA SS800 User Manual

Page 78

Advertising
background image

78

inserted in PCMCIA slot, the mounting point on an NFS server or the SYSLOG server. If the

internal memory is used to store system log data, the log data will be cleared when the Super Series is

turned off. To preserve the system log data, set the storage location to be the ATA/IDE fixed disk card,

SYSLOG server or NFS server. To do this, the user must configure the corresponding media in

advance. Unless the media is properly set up, the user will not be able to select a storage location

from the interface.

System log buffer size

This parameter defines the maximum amount of system log data that can be logged. When using

internal memory to store data, the total size of the system log cannot exceed 300 Kbytes.

When using an ATA/IDE fixed disk card to store log data, the maximum buffer size is dependent upon

the card capacity.

When using an NFS server to store logs data, the maximum buffer size is unlimited. The user should

configure the NFS server to ensure that the port logging system works properly.

When using the SYSLOG server to store log data, the user cannot set the buffer size.

The Super Series can also be configured to send log data automatically if the number of logs unsent

reaches a pre-defined number. If enabled, the user must set parameters to initiate the creation of a

email. These parameters would include the number of logs required to trigger an email, the recipient

email address, etc. Figure 6-2 shows the configuration and system log view screen.

Figure 6-2 System log configuration and view

Advertising