Table 2.8. Product Dimensions and Weights – ANSI/UL

Type

Design

Width

Depth

Height

Weight

in.

mm

in.

mm

in.

mm

lbs.

kg

3-pole

Envelope 1, Top Mounted, UL/ANSI

Fixed breaker - back connected

13.50 343 17.17 436 17.40 442 136.7

62

Drawout breaker - Moving portion 13.07 332 16.34 415 17.24 438 149.9

68

Cassette/substructure

13.50 343 20.83 529 17.44 443 110.2

50

Envelope 1, Side Mounted, UL/ANSI

Fixed breaker - back connected

16.14 410 17.17 436 15.98 406 136.7

62

Drawout breaker - Moving portion 15.35 390 16.34 415 15.83 402 149.9

68

Cassette/substructure

15.83 402 20.83 529 15.98 406 110.2

50

Envelope 2, Up to 2000A, UL/ANSI

Fixed breaker - back connected

17.17 436 17.17 436 17.40 442 165.3

75

Drawout breaker - Moving portion 17.01 432 16.34 415 17.24 438 176.4

80

Cassette/substructure

17.44 443 20.83 529 17.44 443 114.6

52

Envelope 2, Up to 3000A, UL

Fixed breaker - back connected

17.17 436 22.17 563 17.40 442 253.5 115

Drawout breaker - Moving portion 17.01 432 16.34 415 17.24 438 209.4

95

Cassette/substructure

17.44 443 26.14 664 17.44 443 231.5 105

Envelope 2, Up to 3200A, ANSI

Fixed breaker - back connected

17.17 436 22.17 563 17.40 442 275.6 125

Drawout breaker - Moving portion 17.01 432 16.34 415 17.24 438 209.4

95

Cassette/substructure

17.44 443 26.14 664 17.44 443 246.9 112

Envelope 3, Up to 4000A, ANSI/UL

Fixed breaker - back connected

28.98 736 17.17 436 17.40 442 286.6 130

Envelope 3, Up to 5000A ANSI / 6000A UL Fixed breaker - back connected

28.98 736 22.17 563 17.40 442 463.0 210

Envelope 3, All Ratings

Drawout breaker - Moving portion 28.82 732 16.34 415 17.24 438 330.7 150
Cassette/substructure

29.25 743 26.14 664 17.44 443 396.8 180

Envelope 3-200kA, All Ratings

Drawout breaker - Moving portion 28.82 732 16.34 415 17.24 438 339.5 154
Cassette/substructure

29.25 743 26.14 664 20.47 520 407.8 185

4-pole

Envelope 1, Top Mounted, UL/ANSI

Fixed breaker - back connected

17.44 443 17.17 436 17.40 442 180.8

82

Drawout breaker - Moving portion 17.01 432 16.34 415 17.24 438 198.4

90

Cassette/substructure

17.44 443 20.83 529 17.44 443 143.3

65

Envelope 1, Side Mounted, UL/ANSI

Fixed breaker - back connected

20.08 510 17.17 436 15.98 406 180.8

82

Drawout breaker - Moving portion 19.29 490 16.34 415 15.83 402 198.4

90

Cassette/substructure

19.76 502 20.83 529 15.98 406 143.3

65

Envelope 2, Up to 2000A, UL/ANSI

Fixed breaker - back connected

22.28 566 17.17 436 17.40 442 220.5 100

Drawout breaker - Moving portion 22.13 562 16.34 415 17.24 438 242.5 110
Cassette/substructure

22.56 573 20.83 529 17.44 443 154.3

70

Envelope 2, Up to 3000A, UL

Fixed breaker - back connected

22.28 566 22.17 563 17.40 442 330.7 150

Drawout breaker - Moving portion 22.13 562 16.34 415 17.24 438 275.6 125
Cassette/substructure

22.56 573 26.14 664 17.44 443 308.6 140

Envelope 2, Up to 3200A, ANSI

Fixed breaker - back connected

22.28 566 22.17 563 17.40 442 363.8 165

Drawout breaker - Moving portion 22.13 562 16.34 415 17.24 438 275.6 125
Cassette/substructure

22.56 573 26.14 664 17.44 443 330.7 150

Envelope 3, Up to 4000A, ANSI/UL

Fixed breaker - back connected

38.03 966 22.17 563 17.40 442 385.8 175

Envelope 3, Up to 5000A ANSI / 6000A UL Fixed breaker - back connected

38.03 966 22.17 563 17.40 442 617.3 280

Envelope 3, All Ratings

Drawout breaker - Moving portion 37.87 962 16.34 415 17.24 438 440.9 200
Cassette/substructure

38.31 973 26.14 664 17.44 443 529.1 240

Envelope 3-200kA, All Ratings

Drawout breaker - Moving portion 37.87 962 16.34 415 17.24 438 451.9 205
Cassette/substructure

38.31 973 26.14 664 20.47 520 542.3 246