EntelliGuard® G Circuit Breaker

DEH-41304C

Section 3 – Lifting, Mounting and Installation

13 March 14

18

©2012 General Electric All Rights Reserved

Table 3.4. Electronic Interlock

Network Interlock Connections

Network Interlock Status Switch

A5

A6

A7

A8

B4

B5

B6

NI TRIP

NI TRIP

NI RESET

NI RESET

NI NC

NI NO

NI COM

1.9 A

1.9 A

1.9 A

1.9 A

10 A

10 A

10 A

240 V

240 V

240 V

240 V

240 V

240 V

240 V

Table 3.5. Wiring Schematic Nomenclature Definitions

Pin

Nomenclature

Description

Pin

Nomenclature

Description

A1

Motor

power input to motor operator

B1

Input 1

relay input to trip unit

A2

Motor

B2

Input 2

relay input to trip unit

A3

SPR NO/RTC NO

spring charge status contact/
ready to close signaling contact

B3

I/P COM

relay input to trip unit

A4

SPR NO/RTC NO

B4

ST1 NO/NC8

shunt trip 1 signaling contact/normally
open contact 8

A5

ST1

power input to shunt trip 1

B5

ST1 COM/NC8

A6

ST1

B6

UV1 NO/NC7

under voltage release 1 signaling
contact/normally closed contact 7

A7

UV1

under voltage release 1

B7

UV1 COM/NC7

A8

UV1

B8

NC6

normally closed contact 6

A9

CC COM

closing coil neutral wire-common
(CC or CCC)

B9

NC6

A10

CC IMM

closing coil (CC), continuous
control power (CCC)

B10

NC5

normally closed contact 5

A11

CC CMD

closing coil close signal (CCC)

B11

NC5

A12

ST2/UV2

power input to shunt trip 2/under
voltage release 2

B12

NC4

normally closed contact 4

A13

ST2/UV2

B13

NC4

A14

NC3

normally closed contact 3

B14

RELT

RELT signal output

A15

NC3

B15

COM

trip unit communication

A16

NC2

normally closed contact 2

B16

-

-

A17

NC2

B17

CC NO/NO8

closing coil signaling contact/normally
open contact 8

A18

NC1

normally closed contact 1

B18

CC COM/NO8

A19

NC1

B19

ST2 NO/UV2
NO/NO7

shunt trip 2 signaling contact/under
voltage release 2 signaling contact/
normally open contact 7

A20

NO3

normally open contact 3

B20

ST2 COM/UV2
COM/NO7

A21

NO3

B21

NO6

normally open contact 6

A22

NO2

normally open contact 2

B22

NO6

A23

NO2

B23

NO5

normally open contact 5

A24

NO1

normally open contact 1

B24

NO5

A25

NO1

B25

NO4

normally open contact 4

A26

-

-

B26

NO4

A27

O/P1a

relay output 1 from trip unit

B27

ZSI out+

GF zone selective interlock output

A28

O/P1b

relay output 1 from trip unit

B28

ZSI out-

A29

O/P2a

relay output 2 from trip unit

B29

ZSI in+

GF zone selective interlock input

A30

O/P2b

relay output 2 from trip unit

B30

ZSI in-

A31

24 V+

auxiliary power supply to trip unit

B31

ISO GND

trip unit communication

A32

24 V-

B32

5V Iso

A33

BA NC

bell alarm switch

B33

TX EN 1

A34

BA NO

B34

RX

A35

BA COM

B35

TX

A36

N-RC-

neutral Rogowski coil

B36

Voltage Input
GND

ground point for voltage input to trip unit

A37

N-RC+

B37

Volt-A

system phase voltage signals

A38

Eleg-CT

earth leg CT (multi-source ground
fault)

B38

Volt-B

A39

Eleg-CT

B39

Volt-C