SW 838023

GB Shuttle Manual 100316

Appendix

Use the arrow keys to select a new value:
(5 dB increments.)

Confirm the new setting:

The actual setting is shown immediately:
(Value in dB.)

Shuttle

®

is ready for a new selection of a password protect-

ed menu after pressing 'Enter'.
(Re-entering the access code is not necessary if a menu
selection is made within 5 minutes.)

Press 'Escape' if no further password protected menu
selections are needed …

... or confirm with 'Enter' that the changes should be saved,
whereupon Shuttle

®

revert to normal read-out, and the next

password protected menu can be selected.
(Press 'Escape' if the changes should not be saved.)

Max. amplification level
Enter the access code (see page

58

) and press 'Shift' + 'A':

If Shuttle

®

periodically has a system error and/or the level

readout jumps to a high or low level during measuring in
favourable conditions, it may be necessary to limit the ampli-
fication of the received echo. (See also page

66

.)

The effect from electrical noise can also be reduced or elimi-
nated with this function.
Note:

A reduction in the amplification level may affect the
maximum measuring range.

Advertising