Installation


Realisation

2FC4152-1NE00 ... 2FC4222-1NE00

B

A

C

D

X1

X2

E

F

1

ne2bhxn101

Fig. 11: Terminal box 2FC4152-1NE00 ... 2FC4222-

1NE00



Mains cable L1, L2, L3, PE



PE connection mains cable and motor cable



Shielded control cable



Shield connection for the control cable::

1

Prepare cable

2

Pass the cable through the eye of the
shield sheet and bend the eye.

3

Screw together eye and shield sheet:

The shielding must have large−surface
contact to the shield sheet.

The shielding must be connected tightly
to the shield sheet.

0.7 Nm
6 lb-in

PES



Potential free terminal



Control terminal module

X1 Terminal strip for mains connection and relay

output connection

X2 Terminal strip for motor connection and motor

temperature monitoring

PES HF shield termination by large−surface

connection to PE

Mains contactor, fuses and cable cross-
sections

NOTE

Observe the following when using earth
leakage circuit breakers:

 Install earth leakage circuit breakers only

between the supply mains and the frequency
inverter.

 The earth leakage circuit breaker may trip

incorrectly if several drives are
simultaneously connected to the mains.

Frequency
inverter

Required

mains

contactor K1

Type [kW]

[kW]

FI

2)

2FC4152-
1NE00

1,5

2FC4222-
1NE00

2,2

4

≥30 m

A

Fuses and cable cross sections

Frequency
inverter

Installation according

to EN 60204−1

Installation
according to
UL 1)

Type

L1, L2,

L3, PE

[mm

2

]

L1, L2,

L3, PE
[AWG]

2FC4152-
1NE00

M6 A B6 A

1

5 A

18

2FC4222-
1NE00

M10

A

B10 A

1,5

10 A

16

Fuse

Circuit−breaker

1)

Use

only

UL−approved cables, fuses and fuse

holders. UL−fuse: voltage 500 ... 600 V,
tripping characteristic "H", "K5" or "CC"

2)

Pulse current sensitive or all current sensitive

e.l.c.b.