Commissioning

Changing and saving parameters

All parameters for parameterization or monitoring of the controller are stored in codes. The codes are
numbered and marked with a "C" in the documentation. The available codes are listed in the code
table.

Step Keys

Result

Action

1. Connect keypad


XX.XX

Hz

The function

is active.

C0140 = setpoint is indicated via keypad.

2.





Select mode ".

3.



XXXX

Select code..

4.





Modus

off Ahlen.

5.



xxxxx

Parameter onstellen.



Store

Confirm entry when ! is blinking.

6.



Confirm entry when ! is not blinking;



is inactive.

7.

Set parameters

Start "loop" again at 2. for further parameter setting.

Changed parameters are stored in the non−volatile memory of the controller.

5.2.2 Code

table

How to read the Code table

Column Abbreviation Meaning

Cxxxx

Code number Cxxxx

The parameter value is accepted
immediately (ONLINE)



Changed parameter of the code will be accepted after pressing

Code



Changed parameter of the code will be accepted after pressing

if

the controller is inhibited

Designation

Name of the code

Manufacturer

Default setting (value at delivery or after restoring default setting via
C0002)

Further information can be obtained from "IMPORTANT"

Selection

1

{%}

99 Min. value

{unit}

max. value

IMPORTANT -

Brief,

important

explanations

Code Possible

settings IMPORTANT

No. Designation

Manu-
facturer

Selection

C0140 Setpoint offset via

keypad

0,00

-650,00 {0,02 Hz}

650,00 Acts additively on

 main

setpoint.

 setpoint

2.

 fixed speeds

(JOG).

The set value is stored in case of
mains switching or keypad
removal.

C0050 Output frequency

-650,00

{Hz}

650,00 Display only: Output frequency

without slip compensation

C0052 Motor voltage

0

{V}

1000 Display only

C0054 Apparent motor

current

0,0

{A}

2000,0 Display

only