Installation


Mains contactor, fuses and cable cross-
sections

NOTE

Observe the following when using
earth−leakage circuit breakers:

 Install earth−leakage circuit breakers only

between the supply mains and the frequency
inverter.

 The earth−leakage circuit breaker may trip

incorrectly if several drives are
simultaneously connected to the mains.

Frequency
inverter

Required

mains

contactor K1

Type [kW]

[kW]

FI

2)

2FC4302-
1NE00

3 3

2FC4402-
1NE00

4 4

2FC4552-
1NE00

5,5 5,5

2FC4752-
1NE00

7,5 7,5

≥300 mA

Fuses and cable cross sections

Frequency
inverter

Installation according

to EN 60204-1

Installation
according to
UL 1)

Type

L1, L2,

L3, PE

[mm

2

]

L1, L2,

L3, PE
[AWG]

2FC4302-
1NE00

M16

A

B16 A

2,5

15 A

14

2FC4402-
1NE00

M20

A

B20 A

4

20 A

12

2FC4552-
1NE00

M25

A

B25 A

4

25 A

10

2FC4752-
1NE00

M32

A

B32 A

6

35 A

8

Fuse

Circuit−breaker

1)

Use only UL−approved cables, fuses and fuse

holders. UL−fuse: voltage 500 ... 600 V,
tripping characteristic "H", "K5" or "CC"

2)

All−current sensitive e.l.c.b.

Relay data

NOTE

The service life of the relay depends on the
type of load (ohmic, inductive or capacitive)
and the value of the switching capacity.

Technical data

AC 250 V/3 A

DC 24 V/2 A … DC 240 V/0.22 A

Function Relay

position

switched

Displayed

message

X1/K11 Relay output

normally−close
d contact

opened TRIP

X1/K12 Relay

mid−position
contact

X1/K14 Relay output

normally−open
contact

closed TRIP

PES

HF shield termination by large−surface
connection to PE