Servicing


Keypad

(PC)

1)

Malfunction

Cause

Remedy

Carried
out by

Mains voltage too low

Check mains voltage

DC−bus voltage too low

Check supply module

LU


DC−bus
undervoltage

400 V frequency inverter
connected to 230 V mains

Connect frequency inverter to the
correct mains voltage.

Electrician

Short−circuit

Search for cause of short−circuit;
check motor cable.

Operator
Electrician

OC1

(11)

Short−circuit

Excessive capacitive charging
current of the motor cable

Use shorter motor cable with
lower charging current..

Electrician

Grounded motor phase

Check motor, check motor cable

OC2

(12)

Earth fault

Excessive capacitive charging
current of the motor cable

Use shorter motor cable with
lower charging current.

Electrician

Acceleration time too short
(C0012)

 Increase acceleration time
 Check drive dimensioning

U

min

- boost (C0016) set too

large or too small

Correct setting

Only for operation with
control cabinet inverter
2FCxxxx−2NE00
U/f- rated frequency (C0015)
set too small

Correct setting

Differential pressure too high

Check differential pressure of the
system.

Side channel blower starts at
half throttle

 Increase acceleration time
 Open valves.

Operator

Frequency
inverter overload
during
acceleration

Impeller jammed

Repair side channel blower.

Service

*)

Defective motor cable

Check wiring.

OC3

(13)

Short−circuit

Interturn fault in the motor

Check motor.

Electrician

Deceleration time too short
(C0013)

OC4

(14)

Frequency
inverter overload
during
deceleration

Energy backflow in generator
mode operation too high

Increase deceleration time.

Operator

OC5

(15)

Frequency
inverter overload
in stationary
operation

Frequent and too long overload Check dimensioning of side

channel blower.

Operator

OC6

(16)

Motor overload
(I

2

x t - overload)

Motor is thermally overloaded,
for instance, because of
 impermissible continuous

current

 frequent or too long

acceleration processes

Check dimensioning of side
channel blower.

Operator

OH

(50)

Heatsink
temperature> +85
°C

Ambient temperature too high Allow frequency inverter to cool

down and ensure better
ventilation.

Operator

Heatsink strongly polluted

Clean heatsink

 Check dimensioning of side

channel blower..

Operator

OH


Heatsink
temperature> +80
°C

Impermissibly high currents or
frequent and too long
accelerations

 Check load, if necessary,

replace defective bearings

Service

*)