Safety instructions


1.4

Application as directed

Validity of the Operating Instructions

These Operating Instructions are valid for G-BH1e series side channel blowers in conjunction with
frequency inverters equipped with the following frequency inverters:



 

2FC

4

xxx

-

1NE00 1x

35

Type

Supply voltage
4 = 400 V/500 V

Power
(e.g.152 = 15 ´ 10

2

W = 1,5 kW)

(e.g.. 752 = 75 ´ 10

2

W = 7,5 kW)

1NE00 = integrated inverter

Hardware version

Software version

nash_elmo Industries GmbH
Industriestrasse 26
D-97616 Bad Neustadt

Type

Input

Output

Prod.-ID

Version

Prod.-No.

Ser.-No.

1

3

2

ne2bhxn014

Fig. 2: Typschild

These Operating Instructions

 contain instructions bearing on transport and

handling, installation, commissioning,
operation, shut−down, storage, servicing and
disposal,

 must be completely read and understood by

all operating and servicing personnel before
beginning to work,

 must be strictly observed,

 must be available at the site of operation in a

complete and perfectly legible condition.

Operating and servicing personnel

 These persons must be trained and

authorized for the work to be carried out.

 Work on electrical installations may be carried

out by trained and authorized electricians
only.

G-BH1e series side channel blowers in
conjunction with frequency inverters

 are

pump−motor units for generating vacuum

or gauge pressure.

 are used to extract, pump and compress the

following gases:

Air,

Non−flammable, non−aggressive,
non−toxic and non−explosive gases or
gas−air mixtures.

With differing gases/gas−air mixtures,
inquire with the manufacturer.

 are intended for industrial applications.

 are designed for continuous operation:

With increased switch−on frequency (at
equal intervals of approx. 5 times per hour)
or increased gas entry temperature and
ambient temperature, the limit
overtemperature of the winding and the
bearings can be exceeded.

Consultation with the manufacturer is
required for operating conditions of this
kind.

 are equipped with a three−phase drive motor

with mounted frequency inverter.

 are available in the following models:

single−impeller (single−stage)

two−impeller (two−stage) for increased
pressure difference

two−impeller (double−flow) for increased
delivery volume

During operation the limit values listed under
"Technical data" must always be complied with.