Commissioning


Code Possible

settings IMPORTANT

No. Designation

Manu-
facturer

Selection

C0010 Minimum output

frequency

10,00

0,00

{0,02 Hz}

650,00 C0010 only limits the analog input 1

Only valid for units 2BH.−..N.1−.
and 2BH.−..N.3−.with integrated
2FCxxxx−1NE00 inverter

C0011 Maximum output

frequency

86,00 7,50 {0,02

Hz}

650,00 Maximum permissible value: 86

(5000/min)

Only valid for units 2BH.−..N.1−.
and 2BH.−..N.3−.with integrated
2FCxxxx−1NE00 inverter

10,00

Setting for units up to 5.5 kW

25,00

Setting for 7.5 kW unit

C0012 Acceleration time

main setpoint

0,00

{0,02 s}

1300,00 Reference: frequency change 0 Hz ...

C0011

Only valid for units 2BH.−..N.1−.
and 2BH.−..N.3−.with integrated
2FCxxxx−1NE00 inverter

10,00

Setting for units up to 5.5 kW

20,00

Setting for 7.5 kW unit

C0013 Deceleration time

main setpoint

0,00

{0,02 s}

1300,00 Reference: frequency change 0 Hz ...

C0011

Only valid for units 2BH.−..N.1−.
and 2BH.−..N.3−.with integrated
2FCxxxx−1NE00 inverter

52,70

Setting for units 2BH.−..N.3−.

90,90

Setting for units 2BH.−..N.1−.

C0015 U/f−rated

frequency

7,50

{0,02

Hz}

960,00

]

[

*

]

[

]

[

]

[

0015

Hz

f

V

U

V

U

Hz

C

r

r

N

 U

N

= mains rated voltage of

inverter

 U

r

= rated voltage of motor

depending on connection method
acc. to rating plate

 f

r

= rated frequency of motor acc.

To rating plate

The setting applies to the entire
mains voltage range in which the
inverter may be operated.

C0016 U

min

boost (starting

voltage

0,00

{0,01

%}

40,00

Depends on the device

Load−independent rise of motor
voltage at low speeds:
 Reference: rated voltage of motor

(C0090).

 The setting applies to the entire

mains voltage range in which the
inverter may be operated.