Elmo Rietschle G-BH1e User Manual

Page 43

Advertising
background image

© Gardner Denver Deutschland GmbH

43 / 52

610.44521.40.000

Servicing


Malfunction

Cause

Remedy

Carried
out by

Leak in system.

Seal leak in the system.

Operator

Shaft seal defective.

Replace shaft seal.

Service*)

Different density of pumped gas. Take account of the conversion of the

pressure values.
Inquire with Service Department.

Service

Change in blade profile due to
soiling.

Clean impeller, check for wear and replace

if

necessary.

Service*)

Setpoint range wrongly adjusted
at DIP switch.

Adjust setting of DIP switch to the analog
signal

Electrician

Side−channel
blower does not
reach the
required speed
/ pump−motor
unit does not
generate
pressure
difference or
generated
difference is too
low

Setting of maximum output
frequency too low.

Increase C0011.
Max. permissible value= 87 Hz (5000/min)
for2BH11 ... 2BH18.
Max. permissible value= 70 Hz (4200/min)
for 2BH19

Electrician
Operator

Min. output frequency set > 0
Hz. (Default setting= 10 Hz)

Change drive characteristics only under
special circumstances! (Set C0010 = 0 Hz)

Electrician
Operator

Side channel
blower
operates,
setpoints”0”

In C0140 a setpoint has been
set. (Setting of C0140 stored in
non−volatile memory

Set C0140 = 0 Hz if necessary..

Electrician
Operator

Current
consumption of
motor too high

C0016 set too large or too small. Correct setting

Electrician
Operator

Flow speed too high.

Clean pipes. Use pipes with larger
cross−section if necessary.

Operator

Abnormal flow
noises

Muffler soiled.

Clean muffler inserts, check condition and
replace if necessary.

Service*)

Abnormal
running noise

Ball bearing lacking grease or
defective.

Regrease or replace ball bearing.

Service*)

Seals on muffler defective.

Check muffler seals and replace if
necessary.

Service*)

Blower leaky

Seals in motor area defective.

Check motor seals and replace if necessary. Service

*

) Can only be repaired by the operator if the maintenance manual is on hand!

8.1.2 Frequency inverter status indications

LED

red

green

Operating status

off on Frequency

inverter

enabled

on

on

Mains switched on and automatic start inhibited

off

slowly blinking Frequency inverter inhibited

off

fast blinking

Motor parameter identification being executed

fast blinking

off

Undervoltage

slowly blinking off

Fault active

Advertising