88 0h r – Elmo Rietschle G-BH1e User Manual

Page 46

Advertising
background image

610.44521.40.000

46 / 52

© Gardner Denver Deutschland GmbH

Servicing

Keypad

(PC)

1)

Malfunction

Cause

Remedy

Carried
out by

Motor too hot because of
excessive currents or frequent
and too long accelerations

Check dimensioning of side
channel blower.

Operator

Impeller jammed

Repair side channel blower.

Service

*)

OH3

(53)

Temperature
monitoring of the
motor has been
triggered

PTC or thermostat not
connected or defective

Connect or repair PTC or
thermostat.

Service

OH4

(54)

Overtemperature
frequency inverter

Frequency inverter too hot
inside

 Reduce frequency inverter

load.

 Improve cooling

Operator

Mains voltage too high

Check voltage supply

Electrician

Braking operation

 Increase deceleration times. Operator

OU


DC−bus
overvoltage

Earth leakage at motor side

Check motor cable and motor for
earth faults. (Separate motor and
frequency inverter)

Electrician

Pr5

(79)

Internal fault

Defective EEPROM

Contact manufacturer

1 Values in parentheses: error number indicated by the PC parameter setting program (in preparation).
*) Can only be repaired by the operator if the maintenance manual is on hand!

8.1.4 Fault indication reset (TRIP-RESET)

20

28

X3

3

1

OFF

4

6

ON

88

0H

r

01 61

000

1

a

b

c

d

e

j

g

f k i h

PS



‚

m n o

p

q r

Hi

Hz

%sh

rpm

°C

W

m

A

V

Lo

2

5

88888

8888

888

8

a

b

c

d

e

j g f k i h PS



‚m n op

q r

Hi

Hz

%sh

rpm

°C

W

m

A

V

Lo

z
y

w x

v

t

u

s

ne2bhxn355

Fig. 25: Fault indication reset (TRIP-RESET)

How to reset the frequency inverter if a fault
occurs (TRIP−Reset):

 Connect

hand−held keypad to the

communication interface during operation.

 Read and take down fault indication on the

keypad display.

 Inhibit frequency inverter.

 Disconnect

pump−motor unit from the mains.

 Carry out a fault analysis and eliminate the

fault.

 Restart the pump−motor unit.

NOTE

The fault indication "EEr" triggered by an
external encoder can also be reset via a
HIGH−LOW signal at terminal E1 if the fault
has been eliminated in advance.

8.2

Service/ after-sales service

Our Service is available for work (in particular the
installation of spare parts, as well as
maintenance and repair work) not described in
these Operating Instructions.

Advertising