Technical data for the complete system – Burkert Type 8644 User Manual

Page 29

Advertising
background image

8644/phoenix - 25

S

YSTEM

D

ESCRIPTION

Technical data for the complete system

Voltage supply:

Rated voltage

24 V/DC

Tolerance

- 15% / + 20%

Valve types 0460, 0461

- 10% / + 10%

Current carrying capacity:

Contacts

max. 8 A

Valve block

max. 2.5 A

(via connector module left)

Maximum current consumption:

Logic current

I_Log = I_Log_FBKN +

Σ

I_Modul

I_Log

Current consumption logic range

I_Log_FBKN

proportional current in field bus nodes max. 1.25 A/DC
(0.75 A/DC for logic supply; 0.5 A/DC for analog voltage supply)

I_Module

proportional current logic range of the elec. base module max. 15 mA

I_Valve

Valve current - before and after power reduction

Valve type

Valve current

before power reduction

after power reduction

6524

43 mA

26 mA

6525

43 mA

26 mA

6526

96 mA

48 mA

6527

96 mA

48 mA

0460

38 mA

-

0461

38 mA

Temperature:

Storage temperature

- 20 to + 60 °C

Field bus nodes Profibus DP (standard)

0 to + 55 °C

Valve type 6524, 6525, 6526, 6527

0 to + 55 °C

Valve type 0460, 0461

0 to + 50 °C

NOTE

The admissible ambient temperature is depent on the modules used. During
assembly, the crucial factor is the most critical module.

Advertising