A&D Weighing Indicator AD-4405 User Manual

Page 27

Advertising
background image

AD-4405 Weighing Indicator

Page

25

External Input

Item

Parameter

Description

** 0

Not used (No function)

1

ZERO key

2

TARE key

3

NET/GROSS key

4

ON/OFF key

5

PRINT key, ENTER key

6

FEED key

7

Serial data output (Format 1)

8

Serial data output (Format 2)

9

Accumulation (M+)

10

Start batching

11

Stop batching

12

“Over” signal, Gross over and display data out when ON

13

NET weight display when shorting the terminal.

14

Accumulated data display when shorting the terminal.

15

Execute comparison when shorting the terminal.

16

Display by the second unit when shorting the terminal.

17

All keys are enabled when shorting the terminal.
(Ignores F12 setting temporary)

18

Inhibit memory code reading when shorting the terminal.

19

Start averaging to hold

f13
EXT1
Function selection of
external input

20

Release holding data

0 to 17, 19 and 20 Same as f13

f14
EXT2

18

Code Memory (BCD 1)

0 to 17, 19 and 20 Same as f13

f15
EXT3

18

Cord Memory (BCD 2)

*: Initial

settings.

Accumulation

Item

Parameter

Description

10 11 Acc. no (0) / Exec (1)

20 21 Manual (0) / Auto (1)

30 31

+

Only (0) / +/- (1)

f20

[Type2]

Accumulation Mode

40 41 OK only (0) /All data (1)

Left: Sub item, select using the

ZERO

key

Right: Setting, select using the

0

,

1

keys

Initial settings: 10, 21, 31, 41

0

Add data anytime

** 1

Above 5 d

2

Above 10 d

3

Above 20 d

f21
Inhibit region for
accumulation

4

Above 50 d

The selection of the inhibit region
for accumulation.
Do not set f21 0 when Auto
accumulation (f20 21).

d:

division (weighing interval) of first range.

*:

Initial settings.

6.2.

F-Functions

Advertising