36

AD-4405 Weighing Indicator

Output of Accumulated Data

Accumulated data can be output to the serial interface.

Output by manual or automatic, and output data format is selected at f41 of the

F-function setting.

f41

Parameter

Manual/Automatic Format

0

No output

* 1

Manual

2

Automatic

Fixed format

3

Manual

4

Automatic

Format 1(selected at f34)

5

Manual

Accumulated data
output at
accumulated data
display

6

Automatic

Format 2(selected at f35)

Step 1 Press the

TOTAL

key to display

total

and the accumulated data.

Step 2 If automatic output is set, the data is output once at that timing.

Step 3 If manual output, by pressing the

PRINT

key while the accumulated data is displayed,

the data is output.

Fixed data format :

Print out of Accumulated Data

Accumulated data can be print out by the internal printer.

Print out by manual or automatic, and output print format is selected at f61 of the

F-function setting.

f61

Parameter

Manual/Automatic Format

0

No printout

1

Manual

2

Automatic

Format 1(selected at f70)

* 3

Manual

Accumulated
data print out at
accumulated
data display

4

Automatic

Format 2(selected at f71)

Step 1 Press the

TOTAL

key to display

total

and the accumulated data.

Step 2 If automatic print is set, the data is printed out once at that timing.

Step 3 If manual print, by pressing the

PRINT

key while the accumulated data is displayed, the

data is printed out.