A&D Weighing Indicator AD-4405 User Manual

Page 71

Advertising
background image

AD-4405 Weighing Indicator

Page

69

19.

19.

19.

19. 4

4

4

4-

-

-

-20mA Analog Output (OP

20mA Analog Output (OP

20mA Analog Output (OP

20mA Analog Output (OP-

-

-

-07)

07)

07)

07)

The OP-07 analog output option is for sending the weight data to an analog input unit.

The output is a 4mA to 20mA current output proportional to the display reading.

The output data is updated in synchronization with the display update.

Specifications

Specifications

Specifications

Specifications

Output current

4mA to 20mA *

Non-linearity

Less than +/- 0.1% fs

Load resistance 0 to 510

W

Temperature

ZERO

Less than +/- 0.02% fs/°C

Resolution Approx.

1/10000

coefficient

SPAN

Less than +/- 0.02% fs/°C

Output terminal Connector terminal No.1 : + No.2 : - No.3 : FG(Earth)
Accessory

Connector terminal (1) TM-MSTB03STF
AC adapter (1)

Note: Please confirm that the AC adapter type is correct

for your local voltage and receptacle type.

* When set to non-weight display (Calibration,

F-settings etc.), output current is 4mA.

The output current is not adjustable.

Settings

Settings

Settings

Settings

Set f30 1 of the F-Function, and set f31, f32 and f33.

Item

Parameter

Remarks

f30

* 0

No output

Initial setting

Data output

1

Analog output

Must be set to 1

2

Serial in/out 1

Data
output

3

Serial in/out 2

f31

* 0

Displayed value

Initial setting

Output data

1

GROSS weight

2

NET weight

f32
Weight value at 4mA

-999999 to 999999

(Initial setting is 0)

Decimal point is set
at “CALSEt”

Analog
output

f33
Weight value at 20mA

-999999 to 999999

(Initial setting is 10000)

Decimal point is set
at “CALSEt”

Settings of f32 and f33

When entering the f32 or f33 settings (press the

ENTER

key when “32” or “33” is blinking), the

setting value is displayed. Set the value using

the

0

-

9

key. By pressing the +/

key, the

polarity of the value can be alternated. Press

the

ENTER

key to store the setting value into

memory. After this the display returns to selection

of the Function number.

Analog output terminal

()









DC 7V - 10V

AC adapter Jack

+

-

19. 4-20mA Analog Output (OP-07)

Output current

Weight

20mA

4mA

f32 a

f33 a

f32 b

f33 b

a

b

Advertising