A&D Weighing Indicator AD-4405 User Manual

Page 28

Advertising
background image

Page

26

AD-4405 Weighing Indicator

Comparator

Item

Parameter

Description

* 0

Not used

1

Upper/lower limit comparison (2 Limits setting)

2

Upper/lower limit comparison (Target and allowance)

3

Upper/lower limit comparison (Target and % allowance)

4

HH/Hi/OK/Lo/LL comparison (4 Limits setting)

5

HH/Hi/OK/Lo/LL comparison (Target and allowance)

6

HH/Hi/OK/Lo/LL comparison (Target and % allowance)

7

Check weighing 1

8

Check weighing 2

9

Check weighing 3

10

Simple batch 1

11

Simple batch 2

f22
Comparator function

12

Simple batch 3 (Loss in weight)

10 11 Includes zero band(1)
20 21 Includes minus(1)
30 31 Stable(0) /All of the time(1)

f23 (f22 1 to 6)

[Type2]

Validation of
comparison

40 41 All of the time(0)/Start, stop(1)

Initial settings are
11,21,31 and 40.

10 11 Tare when start(1)
20 21 Stop after Full by key(0)/Auto(1)

30 31

Over/Under judgment:
After dribble flow(0) /
Batch finish(1)

f23 (f22 10 to 12)

[Type2]

Sub function for
batch weighing

40 41 No function

Initial settings are
11,21,31 and 40.

* 0

Over

1

Under

f24
Relay output
selection

2

Finish / Full (f22 9,10,12)

Effective when
f22 7,9,10 or 12.

f25
Batch finish output time

0.0 to

9.9

Relay on time by 0.1second step
(00 : continuous to zero band)

Initial setting is 0.0.

f26
Zero band

-999999 to 999999

Initial setting is 0.

*:

Initial

settings.


Hold

Item

Parameter

Description

** 0

Not hold (Hold function is off)

1

Manual hold

2

Auto hold

f27
Hold mode

3

Manual and Auto hold

f28
Averaging time

0.0 to

9.9

Averaging time by 0.1second step
(00 : hold at start time)

Initial setting is 0.0.

*:

Initial

settings.

6.2. F-Functions