A&D Weighing Indicator AD-4405 User Manual

Page 29

Advertising
background image

AD-4405 Weighing Indicator

Page

27

Data Output

Item

Parameter

Description

** 0

No data output

1

Analog output

Set f31, 32, 33

2

Serial output

f30
Data output

3

Serial output (Zero suppressing)

RS-232C,
RS-422/485

*:

Initial

settings.


Analog Output

Item

Parameter

Description

* 0

Displayed data

1

Gross data

f31
Output data

2

Net data

f32
Weight value at 4mA output

-999999 to 999999 (Initial setting is 0)

f33
Weight value at 20mA output

-999999 to 999999 (Initial setting is
10000)

Polarity is
changed by
pressing the +/-
key.

*:

Initial

settings.


Serial Data Format

Item

Parameter

Description

x 0

Terminator

x 1

Device ID (selected at f06)

x 2 Code

number

x 3

Data number *

x 4

Result of comparison

x 5 Date
x 6 Time
x 7 Accumulated

value

x 8 Accumulation

count

x 9

Stable / Over

x a Displayed

weight

x b Gross

weight

x C Net

weight

x d Tare

weight

x e

Weight type (

G /N / T

, refer to Cf06)

f34

[Type3]

Serial data format 1

Initial value
19, 2e, 3a 4f e50



f35

[Type3]

Serial data format 2

Initial value
17 2f e30

x f

Weight unit (cf. Cf07)

ZERO

key :

order of output
(1-999)
“Exxx” indicates
the end of data
to output

NET/GROSS

key:

Expand or
shorten output
data length

0

-

9

,

A

-

F

key

output data

1 The comma of the parameter display indicates that the comma (f46 0, semi-colon

for f46 1) is output after the data. To turn this mark on and off, press the

9

key while

pressing

NET/GROSS

key.

Output of the initial settings of f34(19, 2E, 3A 4F E50) is like “ST,GR,

+12345.6kg”.

2 The data number *(parameter 3) increments automatically with each serial data

output from 1 to 99999 (the next of 99999 is 1). The starting number can be set

using the keys.

6.2.