Installation

70304601

16

Figure 1

TMB2110N

NOTE: Shaded areas indicate adjacent structure.

1

0.5 in. (13 mm) recommended between machines for removal or installation.

2

Allow 2 – 4 in. (51 – 102 mm) opening at top of machine to aid in removal or installation. A removable trim piece
may be used to conceal the opening; zero clearance allowed for trim.

3

4 in. (102 mm) Maximum Header Thickness

4

12 in. (305 mm) Minimum Clearance

5

24 in. (610 mm) Minimum, 36 in. (914 mm) recommended for maintenance purposes.

6

Provision for Make-Up Air: Minimum 1.5 square feet T30 models, minimum 2 square feet T45 models. Location
for reference only. May be anywhere behind tumbler.

7

0.25 in. (6 mm) recommended for removal or installation purposes, zero clearance allowed.

WARNING

To reduce the risk of severe injury, clearance of tumbler cabinet from combustible
construction must conform to the minimum clearances.

W056