Basic configuration, Warning – Alliance Laundry Systems Drying Cabinet User Manual

Page 22

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Installation

70304601

20

Table 3 describes the different gases that are available
in different CE countries, and how the machines need
to be configured to operate with those gases. In the
CE, there are Natural Gas configurations that do not
allow for machine regulation, and L.P. Gas
configurations that must be regulated. For L.P. Gas,
third family B/P at 50 mbar, order regulated Natural
Gas machines and convert according to Table 3.

Basic Configuration

1. Determine the necessary conversion operations to

convert from the factory-supplied configuration
to the desired configuration.

2. Perform the conversions required so the machine

is properly configured for the desired country and
gas (refer to Specific Conversion Procedures
section):

How to Convert Gas Valve from Regulated to
Unregulated

NOTE: Conversion from regulated to unregulated
is only needed when regulated tumblers were
ordered, but unregulated tumblers were needed, or
if the gas supply type is changed at a later date.

How to Change Burner Orifice Size

How to Adjust Gas Valve Governor/Regulator

How to Change Regulator Spring, DE/AT
Only

3. If applicable, peel off the appropriate country

sticker (included with machine) and apply it to
the serial plate over the existing country
information.

4. If applicable, peel off the appropriate conversion

sticker (included with machine) and apply it to
the data plate over the “ADJUSTED FOR ______
GAS: ______” information.

5. Commission tumbler for use.

Figure 6

T103K

1

Gas Shut-Off Valve (Ahead of pressure tap)

2

Pressure Tap

3

Gas Shut-Off Valve (Shown in closed position)

WARNING

When converting the tumbler to a
different gas or pressure, first verify that
the supply inlet pressure is equipped with
a pressure regulator (located ahead of the
tumbler) that will maintain the gas supply
at the inlet pressure specified.

W430

SPECIFIED

LOCAL INLET

PRESSURE

3

2

1

Advertising