Single drop timer – Alliance Laundry Systems Drying Cabinet User Manual

Page 48

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

70304601

46

Single Drop Timer

NOTE: The following information is for
models with an SD control suffix only.

Power-Up Mode

When power is applied to the tumbler, the IN USE
light flashes factory status information. Following this,
the control goes into READY Mode (light off) or RUN
Mode if power was interrupted during a cycle (light
on, time remaining unchanged).

Ready Mode

In READY Mode (light off), the control waits for the
vend to be satisfied. When vend is satisfied the control
goes into START Mode.

Start Mode

In START Mode (light on), the vend has been satisfied
but the start button has not been pressed. Time
remaining in the cycle will not change until the start
button is pressed. When the start button is pressed the
machine goes into RUN Mode.

Run Mode

In RUN Mode (light on), the machine is running a
cycle and the time remaining is counting down. When
time remaining counts down to zero, the control goes
into READY Mode.

Setting Dry Time Dipswitches

To change the dry time on the tumbler, combinations
of dipswitches can be set on the control.

There are eight dipswitches on the tumbler control.
The first six switches are used to program the amount
of additional heat time given for each coin pulse. The
additional drying time is added to the factory default
minimum heat time of one minute. A valve of 1 to 64
minutes of additional drying time is available for each
coin drop pulse.

The last two switches are used to program the amount
of additional cool down time. The additional cool
down time is added to the factory default minimum
cool down time of 1 minute. A value of 1 to 3
additional minutes is available. The control is shipped
from the factory programmed with 1 minute of
minimum heat time, preset with 7 additional minutes
of drying time (dipswitches 1, 2 and 3 in ON position)
and 1 minute of minimum cool down time for a total
time of 9 minutes for a coin pulse. For dipswitch
settings refer to Table 13.

The control reads the dipswitch settings at power-up.
The control must be powered down to change the
dipswitch settings.

To change the time for a coin pulse, the desired dry
time dipswitches must be set to ON position. All other
dipswitches must be in OFF position.