Specific conversion procedures – Alliance Laundry Systems Drying Cabinet User Manual

Page 24

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Installation

70304601

22

Specific Conversion Procedures

How to Convert Gas Valve from Regulated to
Unregulated

NOTE: Conversion from regulated to unregulated
is only needed when regulated tumblers were
ordered, but regulated tumblers were needed.

Johnson GM7000 gas valve:

1. Disconnect electrical power from tumbler. Close

gas shut-off valve to tumbler. Refer to Figure 7.

2. Follow instructions in Conversion Kit, Part No.

431485 (Johnson Part No. GM-70 CBP).

NOTE: This kit does not contain any burner
orifices.

3. Change burner orifice size as required by the

appropriate table according to How to Change
Burner Orifice Size
.

4. Commission tumbler for use.

Figure 7

TMB2135N

1

Gas Shut-Off Valve Assembly (closed position)

6

Required Burner Orifice Pressure

2

Gas Valve

7

Manometer

3

Burner Orifice

8

Hose - Connect Over Loosened Slotted

4

Regulator Adjusting Housing and Gasket

Pressure Tap Screw in Bottom of Gas Valve

(Regulated version shown)

9

Spud Holder

5

Gas Valve Bracket

10

Outlet Pressure Tap

TMB2135N

1

2

3

4

7

9

10

8

6

5

Advertising