Required for ce models only, Installing ce gas drying tumblers, General information – Alliance Laundry Systems Drying Cabinet User Manual

Page 21: Warning

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Installation

19

70304601

9. Wipe out the cylinder using an all-purpose

cleaner or detergent and water solution. Refer to
Figure 5.

Figure 5

If the tumbler does not meet ANY of the listed
requirements, remove tumbler from use. Refer to
Removing Tumbler from Service section

Required for CE Models Only

Once machine is installed, please be sure to complete
the following items:

Review and verify machine operation with

customer.

Leave all literature and a signed Declaration of

Conformity with customer.

Review machine warranty information with

customer.

Apply warning sticker on front panel of machine,

in language appropriate to country of sale
(included in literature packet).

Installing CE Gas Drying Tumblers

General Information

This information is to be used when installing gas
tumblers in countries, and/or on gases, different than
the machine’s factory configuration. Tumblers are
supplied from the factory for operation on Natural Gas
1000 Btu/cu ft. (8914 kcal/m

3

), or L.P. Gas 2500 Btu/

cu ft. (22,250 kcal/m

3

) in the countries of GB/IE/PT/

ES/IT/GR/LU/CH. To install machines in any other
country, or on any other gas, requires some level of
modification.

Burner orifices, stickers, block-open kits, regulator
springs and other parts needed for conversions are to
be ordered separately.

Models are built in two different configurations:

Regulated Natural Gas – Burner orifice is sized

for Natural Gas, second family, group H (E) at
20 mbar inlet pressure. Regulator/governor is
operational. Gas valve CAN be field-converted to
a non-regulating type.

Unregulated L.P. (Liquefied Petroleum) Gas

Burner orifice is sized for L.P., third family,
group 3+ at 28.37 mbar inlet pressure. Regulator/
governor is blocked open. Gas valve CANNOT
be field-converted to a regulating type.

Serial plates supplied from the factory are configured
for the countries of GB/IE/PT/ES/IT/GR/LU/CH.
These instructions pertain to the situations when the
country of use or gas supply is different than that on
the serial plate.

T452I

T452I

WARNING

To reduce the risk of electric shock, fire,
explosion, serious injury or death:
• Disconnect electric power to the

tumbler before servicing.

• Close gas shut-off valve to gas tumbler

before servicing.

• Close steam valve to steam tumbler

before servicing.

• Never start the tumbler with any guards/

panels removed.

• Whenever ground wires are removed

during servicing, these ground wires
must be reconnected to ensure that the
tumbler is properly grounded.

W002

Advertising