Gases and Configurations

Country

Code

Gas Type

Group

Supply

Pressure,

mbar

Burner

Orifice

Pressure,

mbar

Capacity/

Model

Diameter,

mm

Quantity

Burner

Orifice

Part No.

DK/NO/

SE/FI/CZ/

EE/LV/LT/

SI/SK

Natural Gas

H

20

8.0

T30
T45

4.0
4.6

2

M402992
M411371

L.P. Gas

B/P

30

No Governor

T30
T45

2.2
2.5

2

M401011
M401007

DE

Natural Gas

E

20

8.0

T30
T45

4.0
4.6

2

M402992
M411371

L.P. Gas

LL

30

No Governor

T30
T45

2.2
2.5

2

M401011
M401007

NL

Natural Gas

L

25

11.0

T30
T45

4.0
4.6

2

M402992
M411371

L.P. Gas

B/P

30

No Governor

T30
T45

2.2
2.5

2

M401011
M401007

BE/FR*

Natural Gas

E+

20 or 25

No Governor

T30
T45

3.3
3.7

2

M401021
M401000

L.P. Gas

+

28 or 37

No Governor

T30
T45

2.2
2.5

2

M401011
M401007

GB/IE/PT/
ES/IT/GR/

LU/CH

Natural Gas

H

20

8.0

T30
T45

4.0
4.6

2

M402992
M411371

L.P. Gas

+

28 or 37

No Governor

T30
T45

2.2
2.5

2

M401011
M401007

AT

Natural Gas

H

20

8.0

T30
T45

4.0
4.6

2

M402992
M411371

L.P. Gas

B/P

30

No Governor

T30
T45

2.2
2.5

2

M401011
M401007

CY/IS/MT

L.P. Gas

B/P

30

No Governor

T30

T45

2.2
2.5

2

M401011
M401007

HU

Natural Gas

H

25

8.0

T30

T45

4.0
4.6

2

M402992
M411371

L.P. Gas

B/P

30

No Governor

T30

T45

2.2
2.5

2

M401011
M401007

PL

Natural Gas

H

20

8.0

T30

T45

4.0
4.6

2

M402992
M411371

L.P. Gas

3P

37

No Governor

T30

T45

2.2
2.5

2

M401011
M401007

Burner orifice information at 0-2000 feet (0-600 meters)
altitude.

*

For Natural Gas, Group E+ applications, convert
using L.P. Gas model and replace burner orifice(s).

Table 3